Please upgrade your browser to improve your experience. Browse Our Combi Boilers. Introducing the Logic Plus Combi The efficient and dependable Logic Plus Combi model is a combination combi boiler , which means it can provide your home with central heating as well as instant access to hot water for your taps and showerheads. Summer Conditions When the sun is shining outside , rotate the Mode knob you can find it on the far right of the panel , turning it to the icon that has an image of a tap summer.
Next, turn the central heating demand on the external controls to OFF. Winter Conditions Set the Mode knob to the icon showing a tap and a radiator winter. Next Page. Wall mounted, room sealed, condensing combination boiler 9 pages. Page 3: Natural Gas Only G. Appliance No. Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency.
The boiler will repeat the ignition sequence. The fusing should be 3A. CH temperature control H. Condensate Drain D. Check that the electricity supply to the boiler is off. CH and DHW required. Logic Max Heat. Logic Max Heat Downloads Select a document from the list below to download.
Mexico HE. Mexico HE Downloads Select a document from the list below to download. Evomax Downloads Select a document from the list below to download. Cylinders Downloads Select a document from the list below to download. Electronic Heating Controls. Electronic Heating Controls Downloads Select a document from the list below to download.
Mechanical Heating Controls. Mechanical Heating Controls Downloads Select a document from the list below to download. Accessories Downloads Select a document from the list below to download. Drain down the boiler. Unplug the electrical lead. Unscrew the thermistor to facilitate removal a 13mm socket spanner should be used.
Fit the new thermistor using the sealing washer provided. Point 2. Remove the charge point cover. Recharge the tank pressure to 0. Re-assemble in reverse order 5. Check operation of the boiler. At 25 expect 9, - 10, Ohms At 60 expect 2, - 2, Ohms At 85 expect Are the Timer and the Room Thermostat switched Page Spare Parts When replacing any part on this appliance use only spare parts that you can be assured conform to the safety and performance specification that we require.
Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers. Failure to do so could affect safety or performance of this appliance. Page 59 Benchmark Commissioning and Servicing Section It is a requirement that the boiler is installed and commissioned to the manufacturers instructions and the data fields on the commissioning checklist completed in full. To instigate the boiler guarantee the boiler needs to be registered with the manufacturer within one month of the installation.
If the boiler requires conversion to operate with a different gas family e. Page 64 Ideal Boilers provides after-sales assistance and Technical advice for i combi boilers Ideal Technical helpline: Ideal boilers p. Ch and DhW required. When the Weather Compensation option is fitted to the system then the CH Temperature Control C becomes a method of Ensure the mode knob control A is set to winter controlling room temperature.
Page 68 Loss of system water pressure Condensate Drain The gauge H indicates the central heating system pressure. If the This appliance is fitted with a siphonic condensate trap pressure is seen to fall below the original installation pressure of system that reduces the risk of the appliance condensate bar over a period of time then a water leak may be indicated.
Timer Control Permanently ON 2. The boiler has a call for central heating but the appliance has reached the desired temperature set on the boiler. The boiler has a call for hot water but the appliance has reached the desired temperature set on the boiler. Page Fault Codes 5 Boiler Resets in 15 minutes 1. Turn power off and on at the fused spur. If the boiler fails to operate please contact Ideal Boilers if under warranty or alternatively a Gas Safe Registered Engineer if outside of the warranty period.
This manual is also suitable for: I 30 I Print page 1 Print document 73 pages. Rename the bookmark.